Thursday, 27 June 2019

coupling - Can people act like antennas?


I was watching my oscilloscope as I was holding a very short wire attached to the probe. It was showing about 0 voltage (small spikes) until I touched the metal. When I touched the metal, the scope immediately showed a 60.0Hz (peroid of 16.66ms), approximately sinusoidal (very noisy) waveform. Considering that the power in my area is a 60Hz AC, I think it most likely that it was picking up coupling from the power lines. This sine wave was immediately replaced with a flat, -200mV line when I touched an electrical ground, but resumed when I let go.


Was I acting as an antenna for electrical noise from the mains line? I was wearing rubber shoes on a concrete floor and touching nothing but the probe.



Answer




Antennas are usually thought of as converting a radio wave into an electrical signal. I say this because you wouldn't name the plates of a capacitor as antennas. Capacitive coupling (not EM antenna reception) is the phenomena you witnessed when you touched the o-scope probe.


You might have heard about fluorescent lamps lighting up when pointed at overhead wires: -


enter image description here


The alternating electric field produced by the overhead lines cause a small current to flow through the lamps and light them - this is the same principle involved when touching the scope probe. Picture taken from here. If there were an earthed shield above the tops of the tubes and below the overhead wires, those lamps would not illuminate.


Your body has a large surface area and this massively increased the capacitance between probe tip and the local conductors supplying over one hundred volts RMS around your building.


When you also touched earth, this galvanic electrical connection would dominate the capacitive "connection" to your AC power wiring and the "picked up" signal reduced significantly.


It's all about potential dividers formed by capacitors and resistors and not really about antennas (RF electromagnetic wave devices).


And the presence of the human body can reduce signals reaching (say) a sensor plate: -


enter image description here


Here, the hand (and its capacitance to ground) diverts the electric field from hitting the "receive" plate and less current flows into that plate.



No comments:

Post a Comment

arduino - Can I use TI's cc2541 BLE as micro controller to perform operations/ processing instead of ATmega328P AU to save cost?

I am using arduino pro mini (which contains Atmega328p AU ) along with cc2541(HM-10) to process and transfer data over BLE to smartphone. I...