Saturday, 3 June 2017

Transformer winding ratio vs actual winding count


Output voltage of transformer depends on ratio of winding count on primary and secondary coils, but is there an impact on transformer performance by actual winding count?


Say, i want to have 1:2 ratio, i could wind 10:20 or 100:200 windings.



In general, more windings - bigger the resistance, inductance and cost. Is there any point in winding more or is winding count kept to absolute minimum? How minimal winding count is determined?



Answer



The induced magnetic field is proportional to ampere-turns, that's current times number of turns. Electrical energy is converted to magnetic energy in the core and back to electrical. The core must be big enough to hold that without saturating. For a 100 VA transformer you want to transfer more energy magnetically than for a 10 VA transformer. The 100 VA is larger because it has more turns to build up a stronger field, and also needs a bigger core to avoid it saturating.