Thursday, 25 August 2016

Which are the safety recommendations for soldering?


I was reading about tin alloys for electronics soldering and found it it has about 40% of lead in composition. Lead, everyone knows, it's very dangerous to breathe due to being a heavy metal. Also, I found some recommendations using the combination of an exhauster and a respirator when working with soldering. Is there any international regularization of which respirator type should I use? If not, which type do you recommend? Beyond this, is there any additional safety equipment recommended?


For economics reasons and for better soldering resistance, I've already discarded Pb free solder reflow.



Answer



The dangers of breathing soldering vapor has nothing to do with lead content of the solder. The vapor pressure of lead is so low at soldering temperatures that there just aren't that many lead molecules in the air.


The hazards of breathing soldering vapors is due to the flux getting vaporized, and sometimes parts of components emitting gasses when they get too hot. Lead solder is actually a little safer in that regard since soldering temperatures are lower. However, the biggest variable is the composition of the flux.


If you are worried about this, get something called a fume extractor. This is a little box with a fan and a filter. You place it right next to where you are soldering. It pulls the vapor from soldering away from you and thru its filter. By the time the vaporized stuff gets to the filter, it's no longer vaporized but a bunch of small particles. The filter removes these particles from the stream before exhausting it out the back.


switches - Caps on tactile switch


I know that caps do exist for 12x12mm tactile switches:



and such caps are very standard, we can find a lot.


But is it possible to fit caps on 6x6 mm or 8x8mm or 10x10mm tactile switches? (not sure if 8x8 or 10x10mm are common or not)



I'm not looking for shopping advice (I know how to order by a supplier), but to know if it's common or not to see caps on such small switches.





Wednesday, 24 August 2016

How to determine which wire is which on a transformer?


Let's say I have a transformer with 3 coils. When primary coil is connected to 230V, two secondaries output 12V. Wires are color coded, but I don't know what colors stand for and there is no information about that on manufacturer's website.


Is there any relatively easy way to determine which wire is primary, which is secondary and which is start to the secondary and which is end of the secondary coil?



Answer



In a step-down transformer, the primary winding will have a higher resistance. The resistance will be low, but there should be a noticable difference unless you've got a really big transformer.


If you're trying to identify what a winding is, then here are some notes:



  • If 3 wires have continuity, then you probably have a center-tap winding (+, 0, -)


  • If only 2 wires have continuity, then that is a simple winding.

  • If 4 or more wires have continuity, then you have a multi-tap transformer winding.


Transformer windings have a phase relationship, but it's typically not important for power supplies. Unless one of the wires has continuity to the transformer core, the polarity doesn't matter.


A relatively safe way to test transformers is to hook up a small AC voltage (1-5VAC) and measure the voltages across the other windings.


pcb design - How to connect same signal pads in Package Editor in Eagle?


So, I'm trying to make a circular pad for a project:


enter image description here


To try to make my life easier when changing inner and outer diameters I created a package which consists of 2 pads: one horizontal, which connects one "fin" to the next one, and a vertical one, which is the fin itself.


The "origin" distance is the radius of the pad.


enter image description here


My problem is, I don't want the "unrouted" yellow connection between the pads since they're already touching, and the Package editor doesnt have the route command.



Is there a way that does not involve using the "wire" command and trying to guess the pad center? (I'm not sure if even this would work).


enter image description here


p.s.: I know if I just ignore the request to route it, I'll probably be fine. But I'd like to know if there's a proper way of doing it.



Answer



If you are using Version 6 or later, in the device editor, use the Append button.


In the connection screen, make your connections as normal. Then if you want more than one pad in the package to be connected to the same pin in the schematic, do the following steps.



  1. Click on the connection to which you want to append a pin

  2. Click on the pad to be appended

  3. Click the append button



You should now see more than one pad name forming the connection. There is also a small symbol which looks like a trace connecting some pins (highlighted red). This indicates the type of appended connection.


If the blue line is present in the indicator, it says that they must be connected by a trace in the layout.


If you click on it, the blue line will go away. This now indicates that only one of the pins need be connected (you can connect more, but only one is needed).


In your case, you can use the latter option in a sort of "hacky" way. As you know that the pads are already electrically connected in the footprint, you can click the button to indicate that only one needs to be connected in the layout (as you know they are already connected anyway). This will remove the air wire that is annoying you.


Appending Pin


A basic question about load balancing and power factor correction in three-phase systems


I know basically about phasor representation of line voltages and active reactive power concepts in three-phase systems.



But what I'm wondering is the reasons of two things I hear a lot.


1-) What is the main reason for balancing the loads in a three-phase system. Maybe for a three-phase induction motor the reason is more clear. But imagine a house power entry with three line voltages as phase A, phase B and phase C; one neutral and one earth into the building. As far as I know the loads on all phases must be somehow balanced.


Does that mean they should carry same amount of currents? Does that also mean their power factors should also be close? What is the real reason behind all these balancing?


2-) I also hear about PF compensation with capacitors. What is the main reason to make the power factor close to 1? Why is the power factor adjusted?



Answer




What is the main reason for balancing the loads in a three-phase system. Maybe for a three-phase induction motor the reason is more clear. But imagine a house power entry with three line voltages as phase A, phase B and phase C; one neutral and one earth into the building. As far as I know the loads on all phases must be somehow balanced.



Answers to your more recent question tell you that statistically, loads are expected to be balanced due to the number of simultaneous consumers but, there are no guarantees that all three phases will have equal magnitude currents and, some current will inevitably flow down the neutral connection.




Does that also mean their power factors should also be close?



It would be nice for the generating companies if the individual PFs and currents were balanced but this won't happen and there will be differences that the generating system has to cope with.



What is the real reason behind all these balancing?



To avoid too much current being taken down one single phase wire is a significant reason. This can unduly affect the voltage seen on some phases with respect to neutral and there are rules to follow that limit how far out this voltage supply can be. If one phase is drawing a lot of current with respect to the others, its local load voltage might be driven down too much. Conversely, there are situations when this happens that the phase voltages of under-utilized lines will increase.



I also hear about PF compensation with capacitors. What is the main reason to make the power factor close to 1?




PF correction sets out to reduce the current taken down power lines. Consider this picture: -


enter image description here


The green line is important because it is the real power you get billed on but, many appliances also use reactive power that adds to the current taken by appliance. That reactive power is the vertical blue line. Together, reactive and real power produce the apparent power i.e. the VA (volt amps) you could measure with a voltmeter and ammeter.


Note that the apparent power can never be smaller than the real power and this means that the current supplied by the generating station is higher than what is needed to produce X kilowatts for the consumer.


So, PF correction sets out to add capacitors across the load in an attempt to reduce reactive power to close to zero. This makes PF = 1.


Most traditional power loads are motors and they have an inductive current that is in the direction of the "pointing-up" blue line. If you add capacitors these naturally have a pointing-down blue line hence the two effects cancel out.


It's exactly the same when you have a parallel tuned circuit - the impedance becomes high at resonance therefore the current drops leaving just the current needed to supply the "kilowatts".


This sort of PF correction is for the benefit of the power companies in that the net current they have to feed down lines is smaller. This means that thinner cables are needed.


What gauge of single strand wire works well with breadboards?


I bought some single strand wires hoping to prototype on the breadboards. Unfortunately it was too small to properly fit into the breadboard holes.


So my question is which gauge fits well on those small holes of breadboard?



Answer



Plain single stranded copper wire works fine in these breadboards. That's what I primarily use. I find 22 guage is about right.


Fancy specially made jumper wires may be more reliable in the long run, but cutting a piece of wire off a roll and stripping the ends is easy and quick. You can do that many times for the cost of one jumper wire.



A while ago I bought a set of pre-cut and pre-stripped wires for this use from Jameco. It sounded like a good idea at the time. Having the wires ready to use is nice, but they stupidly decided to bend the stripped ends at right angles right where the insulation ends. That makes them difficult to use except for the ones that only go 1, 2, or 3 holes. As I cut and strip more jumper wires from a 500 foot roll of #22 wire, I put them into the box the Jameco kit came in according to their lengths. Over the years, the stripped ends of a few wires have broken right at the end of the insulation. This happens quite rarely, so the trouble to cut and strip a new wire is nothing.


Need help understanding DALI circuit and 220 VAC protection


I am making a circuit to interface my MCU with a DALI bus. My basic circuit works and I am able to communicate on DALI bus. It looks like this:


working dali ckt


I fully understand the above circuit.


After my base circuit was done, I found out that DALI bus should be protected against accidental 220 VAC connection on the DALI bus. I have no clue how to proceed on this. I found a document online which gives this circuit but doesn't explain anything about it:


protected circuit


Can you please help me understand how this circuit works in following conditions:



a) What happens when a data packet is received on the bus in working voltage range (16 V typical)?


b) What happens when the MCU tries to send a data packet in working voltage range (16 V typical)?


c) What changes when there is 220 VAC on DALI bus? How does this circuit work to prevent a failure in this situation?


Thanks




arduino - Can I use TI's cc2541 BLE as micro controller to perform operations/ processing instead of ATmega328P AU to save cost?

I am using arduino pro mini (which contains Atmega328p AU ) along with cc2541(HM-10) to process and transfer data over BLE to smartphone. I...