Context: tuning the control loop of a buck SMPS. I specicifally have a TI TPS40200-based circuit in mind, but I think this applies to SMPS design in general.


Quoting from Type 2 compensation network:


Mr. Maniktala suggests that the loop gain transfer function of the switcher intersect
the 0 dB point at approximately 1/6th the switching frequency, with a slope of -1.

I have heard this before from another engineer, but did not get a chance to ask why. What is the reason the crossover frequency of the control network should be a fraction of the switching frequency? Why specifically around 1/5th or 1/6th?


Are there any other desirable traits when designing a compensation network for an SMPS controller other than the most basic criterion of >45 degree phase margin for system stability?



Answer




A switch mode power supply is essentially a sampled-data system, therefore the theoretical maximum bandwidth is one half the switching frequency. Practically the phase and transport lag there make it impossible to close the loop there, so 1/5 to 1/10th the switching frequency is a good rule of thumb.


There are many other considerations in compensating an SMPS- Gain margin, conditional stability, current vs. voltage mode, slope compensation, transient response, etc.


Check out www.ridleyengineering.com, there are lots of good free tutorials and papers there.