Tuesday 9 April 2019

Is there any wearout mechanism for a relay simply from current flowing?


How will the wear of a relay be affected if the current through the relay is brought to zero before the relay is operated?


I'm thinking about having a solid state relay in series with 3 mechanical relays. The 3 mechanical relays will all be connected to the output of the solid state relay, and channel the current to one load each. Thus there are three loads, and three mechanical relays. I can arrange to turn off the solid state relay before opening or closing any of the mechanical relays.


Can I assume that the lifetime of the mechanical relays will be equal to the speciefied mechanical lifetime of the relay, or will current flowing through the closed relays somehow cause aging in and of itself?



Answer



Yes, you can most likely use the mechanical lifetime for this purpose. However I have to question your premise a bit.


The SSR (assuming it's an AC type, you don't say) will likely have an internal snubber so that there will be a small current surge at switching (depending on where in the AC cycle it switching) but it's unlikely it will reduce the lifetime by much.



Still might be worth testing if this is an important point. 10^6 operations at 1 per second will only take a couple weeks.


No comments:

Post a Comment

arduino - Can I use TI's cc2541 BLE as micro controller to perform operations/ processing instead of ATmega328P AU to save cost?

I am using arduino pro mini (which contains Atmega328p AU ) along with cc2541(HM-10) to process and transfer data over BLE to smartphone. I...