Thursday, 14 January 2016

usb - Crazy homebrew 500 MHz 1 Gs/s oscilloscope possible?


I was reading USB scope probe - request for comments and ideas, and it got me thinking. What I'd really like is a very high performance oscilloscope, one which would cost $10000 or so. Surely many other people would like one too. And surely, with the expertise available on this site, it should be possible to design and open-source one.


Here's my idea:



  • It would be a hand-held 'scope probe with a USB lead coming out.


  • Battery operated to isolate it from USB power.

  • Input stage is a high speed op-amp, like THS3201DBVT?

  • ADC is something like ASD5010, which is 1 Gs/s and 650 MHz input bandwidth.

  • FPGA to handle the 32-bit data coming out, do the triggering, and package it into the USB.

  • Open-source software to run on the PC.


Is this a fool's errand? What am I missing?


Added, more details in response to the answers:



  • This 'scope would not be able to compete with the fancy expensive scopes out there. The main aim is to have something which would make it possible to examine high speed signals, while costing less than $200 for someone to make themselves.


  • USB bandwidth: This is not an analog scope, nor is it a fancy LeCroy. However, USB is quite capable of transfering 2k samples at 60 Hz. This still makes it extremely useful, even though it might not be capable of capturing transient events in between those frames.

  • A clear responsive display. Well, a PC's monitor is certainly clear. Better than almost all scopes on the market. So clarity and size are no problems. Responsive? As long as the screen can be updated at 60 Hz, I think that's pretty responsive.

  • Triggering: I was imagining simple level triggering happening on the device. Again, it would not be able to compete with fancy scopes, but remember: this is supposed to be a $200 device.

  • It's not supposed to have 1 GHz bandwidth. Where did I say that? But surely it could have more than 100 MHz bandwidth?


Take home points:



  • It's a $200 device.

  • The main aim of the device is to make it possible to see high speed signals without spending $10000.

  • There would be many things that it would be unable to do.


  • Surely something like this would be fairly useful to people here.

  • Surely, with the expertise available on this site, we could make it happen?



Answer



This comes down to a question of bandwidth and latency. For a simple system let's assume one probe with 100 MHz bandwidth with 1GS/s sampling rate and an 10-bit A/D converter (I've had bad experiences with 8-bit scopes).


I want a real-time display on the PC with a minimum sampling window of let's say 10ns - 1 cycle of a 100MHz sine wave and a maximum window of (I'll be generous to you in this) half a second. In other words, the lowest time setting will be something like 1ns/div and the highest is .05s/div. I also want several voltage modes - 100mV range up to 20V let's say.


What kind of data rates does this involve?


1Gs/s * 10 bits/sample = 10Gbits/s


Those aren't USB speeds. Far from it. And I didn't even take overhead into account. First off, you just don't have the bandwidth. And it's not just bandwidth either. For your real-time display you need to be consistent. You need to transfer 100 bits to your application layer every 10 nano seconds. That kind of consistency can't be had from USB. It's not designed to cater to one device with extravagant demands - it's designed as a bus. And you can't control when you own the bus - the devices are just slaves. If the host lets another device talk when you need to send data, your data is lost.


You may be crying foul - why transfer real-time data to the computer when 'real-time' for a person is 60Hz? If all you need to do is update the display you certainly don't need that much data. Except you do - your display is some linear combination of all of the samples you've collected. Averaged, least-mean-square approximated, cubic spline interpolation - it doesn't matter. To make a nice pretty display that isn't just a bunch of dots, you need most to all of that data and you need to post process it. Any triggering? The calculations have to be done on the host - at the application layer. No matter what way you slice it, for real-time displays at 1GS/s rates for any accuracy worth a damn, you have to transfer orders of magnitude more data than USB can handle and you have to do it more reliably than you're guaranteed by USB.



What are the ways around this? Don't do a real-time display. Some USB scopes only offer triggered modes. The triggering is handled on the device and when a trigger is found, data is collected in a buffer. When the buffer fills, the USB scope slowly transfers it to the application and then the application displays it. That suffices for lot of scope use, but it's not real-time. And the transfer - that takes a while too. It's inconvenient. And usually the drivers suck. You can tell I've had bad experiences.


I've always wondered why Firewire wasn't used for scopes. It avoids some of the headaches of USB. It's peer-to-peer, offers isochronous (consistent timing) modes and is relatively high bandwidth. You might be able to make a 10MHz real-time scope or so with that.


To address your points after the edit:




  • The usability of a scope goes up tremendously with price. When you make the jump from a $200 USB scope to even a $500 standalone you get tremendous increases in features and basic functionality. Why spend just $200 when for a little bit more you can get a real scope? Now that China has opened up the floodgates of cheap, effective scopes, there's little reason to want to save $300 that will just frustrate you later. The 'fancy' scopes that have these features are cheap nowadays.




  • Yes, limiting your data transfer to only provide something around 60Hz-worth of consistent data will be easier with USB, but that's still not something you want to do. Don't forget about your DSP classes - only grabbing certain data from the stream amounts to decimation. When you decimate, you have to add antialiasing filters. When you do that, you lose bandwidth. This makes your scope less useful - it will limit your bandwidth on the real-time display (and only for real-time - triggered modes would be okay) to much less than the bandwidth of your analog front-end. Managing the signal processing aspects of an oscilloscope are tricky business.





  • Clear responsive display? The PC? Not consistently. Regardless of how you do this, you need to buffer data. As I said before, USB doesn't guarantee when your data gets through. I'll say it differently: USB is not designed to accommodate hard real-time data transfer. Sure, for sufficiently small amounts of data at large intervals you may get some good performance, but not consistent performance. You WILL use buffering and once in a while you WILL miss transferring your buffer in a timely manner. Then your display skips, data is stale, etc. etc. Clear and responsive real-time displays require hard real-time data links, period.




  • Simple triggering - again, we get back to cost vs. complexity vs. responsive. To do triggering on the device to detect transients your device can't just be a dumb data pipe that transfers samples irresponsibly over USB. You have to buffer, buffer, buffer samples on the device until you see your trigger condition. That means you need memory and intelligence on your device - either a large FPGA or a large microcontroller. That adds to size and space. If you use an FPGA you have to balance the amount of triggering logic with your need for lots of RAM for buffer space. So your buffer is smaller than you'd like it to be already. That means that you get a miniscule amount of data around your trigger point. Unless you add external memory - then you can do more. That increases the size and cost of your device though - this certainly won't be just a probe with a USB cable attached to it.




  • You'd be lucky to get 100MHz bandwidth - usually 10x the sampling rate is considered the minimum cutoff for bandwidth. So if you have 1GS/s sampling rate that barely gets you 100MHz bandwidth. You can't get more - a 200MHz square wave is going to look like a 200MHz sine wave. That sucks. That's dumb - it's nowhere near professional level.





Your other set of points:



  • $200? How do you figure? What's the parts list?

  • Good scopes to read high-speed signals do not cost thousands of dollars. They cost maybe A thousand dollars. 100MHz is child's play in the scope department and your idea won't even meet that benchmark as well as a $1000 scope

  • Yes, from the way you describe it it would be very limited indeed. The technical aspects of even the few requirements you have mean a very limited device.

  • It wouldn't be nearly as useful as the $1100 scope I bought with a logic analyzer and 60MHz analog bandwidth. I'd rather pay for my test equipment that dick around with intentionally-limited child's toys.


You live and die by your test equipment as an engineer. If you're not certain you can trust it you're wasting your time. Given the lack of expertise you've shown about high-speed communication, signal processing and the power of embedded processing (in FPGAs or microcontrollers) I wouldn't wager you're up to designing it yourself and no one else who's answered is anything other than ambivalent.


If there were a better-targeted set of requirements that hit upon a real need in the community that wasn't being served, that I could see being technically feasible I'd be on board. But your vague requirements don't seem researched. You need to do a survey of the available options out there for hobbyists - what USB scopes and standalones are people using, what are their strengths and weaknesses, and determine if any niches aren't being filled. Otherwise this is just fantasizing.


No comments: