I am designing a machine and trying to make it look aesthetically pleasing.
Could I use off the shelf USB Type-C to Type-C cables to handle both power deliver and encoder data to/from a motor?
The DC motor is about 80W (@24 V) and uses 2 leads for power and 8 for the encoder. Could I technically use just one USB type cable to achieve this? I would not use the type-c connector, just the cable. The encoder has differential wires so hoping interference would not be an issue.
I understand that passive type-c cables are rated for only 3A but is that limitation due to the cable or the connectors and electronics in them?
Answer
Can all USB Type-C to Type-C cables themselves handle 100 W?
That's really not the right question since the power (hopefully) isn't consumed in the cable. When choosing a cable you need to be mindful of:
- Current carrying capacity. This is affected by wire material (Al, Cu, etc.), cross-sectional area and its ability to dissipate heat in the working environment (free-air, conduit, etc.) without melting the insulation.
- Voltage rating. How many volts can the insulation withstand between cores and between cores and ground.
- High frequency requirements. This is beyond the scope of this answer but includes EMI, cross-talk, shielding, etc.
- Acceptable voltage drop. Voltage drop will be proportional to the product of length and current. To meet the maximum allowed voltage drop requirements the cross-section area of the wire may have to be increased.
So a better question would be:
Can all USB Type-C to Type-C cables handle 3.5 A at 24 V.
Figure 1. Hybrid power and data cables for servo applications. Source: MacRAE'S BLUE BOOK.
Depending on the size of your project it may be worth searching out suitable quantities of hybrid servo cable. Lapp, for example, do a wide variety but you may have difficulty buying in small quantities.
No comments:
Post a Comment