Wednesday, 16 August 2017

Current carrying capacity of 28 AWG wire?


This SCSI cable is composed of 28 AWG twisted pairs. According to an L-Com "tip", such a twisted pair should be able to carry at least 3*0.8=2.4 Amps per conductor. However, this other web site which references the Handbook of Electronic Tables and Formulas suggests that you can carry only 226 mA per conductor. This is an order of magnitude difference! Can anyone explain which one is correct?


The application requires the conductors to carry 1A at 5V DC. So the question really comes down to whether I need one pair or more than one pair.


EDIT:


As David correctly assumed, only one pair will be carrying this current, and 1A is the most current I expect that pair to carry. All other pairs will carry at most 50 mA worst case per wire, typically much less than that, and all the other pairs combined are current limited to 150 mA.



Answer



I am assuming you are going to use only one twisted pair (out of the 34 available) for 1 A. In that case, you should be fine for your application using 28 AWG copper assuming that your cable is surrounded by open air at 30 °C or cooler. The first link's recommendation is close to the (United States) National Electric Code formula. Note that the fine print for the second link says that the power transmission values are "very very conservative."


If more than one twisted pair is carrying a significant amount of current or the cable will not allow heat dissipation, use multiple pairs to carry your current.


No comments:

Post a Comment

arduino - Can I use TI's cc2541 BLE as micro controller to perform operations/ processing instead of ATmega328P AU to save cost?

I am using arduino pro mini (which contains Atmega328p AU ) along with cc2541(HM-10) to process and transfer data over BLE to smartphone. I...